Steel Pipes Knowledge steel-pipes-knowledge

Your position:Home > Steel Pipes Knowledge > Curtain wall construction and maintenance

Mobile: 008618202256900

Contact us Email:steel@fwssteel.com 

Feed and Linkedin page

Recent posts1

Curtain wall construction and maintenance

The construction curtain wall installation projects with construction height of 50m or above shall comply with the relevant provisions of the Safety Management Measures for Relatively Dangerous Partial and Partial Projects issued by the Ministry of Housing and Urban-Rural Development. The unit components of the unit-type glass curtain wall and the assembly components of the hidden frame glass curtain wall shall be processed and assembled in the factory, and the components shall not be processed on the site. The production of glass curtain wall components shall have a complete factory gluing record, and can be traced. Silicone structural sealant shall not be injected on site except for all glass curtain walls. The physical properties of the curtain wall shall be tested before the construction of the building curtain wall, and the samples submitted for inspection shall be consistent with the engineering design. The test report must be attached with the sample structure drawing, and the axis and elevation shall be marked in the drawing, and the test results shall meet the design requirements. The pressing plate on the outside of the open-frame glass curtain wall shall be continuously installed and shall not be fixed in sections. Rear insulation strips shall be continuously installed and fixed.

The pulling capacity of anchor bolts in the rear embedded parts shall be tested on site in accordance with the national standards. The ultimate bearing capacity of field test should be more than 2 times of the design value. Light filled walls shall not be used as supporting structures for curtain walls. The acceptance of the curtain wall project shall conform to the provisions of the relevant project construction standards. The acceptance of concealed works shall also provide corresponding graphic and video data. In areas where typhoon, rainstorm and other bad weather are involved, tests of drenching and reliability shall also be carried out. The curtain wall shall be taken as an important part of residential project inspection and acceptance. When the curtain wall project is completed and accepted, the curtain Wall Operation and Maintenance Manual shall be provided to the owner, the contents of which shall conform to the technical Specifications for Glass Curtain Wall Project and other relevant engineering construction standards. The owner is responsible for the safety maintenance of the hidden frame glass curtain wall. After the completion and acceptance of the building curtain wall project, the owner of the building curtain wall shall meet the following provisions and entrust the institutions with the corresponding engineering design, construction and testing qualifications to conduct regular security risks investigation:
The curtain wall of the pull rod or cable structure shall have a comprehensive pre-tension inspection and adjustment six months after the completion of acceptance, and then every three years; (3) After 10 years of use of curtain wall engineering, sampling inspection should be carried out on the bonding performance of structural silicon sealant in different parts of the project, and then every three years; (4) For the office glass curtain that continues to be used beyond the designed service life, the owner shall organize experts to carry out safety assessment and carry out the assessment opinion.

Tel: +86 18202256900 Email: steel@fwssteel.com

Name:
Email
Leave a message: